Description
IFM Electronic LDL201 IND CONDUCTIVITY HYG ASF-V 077 inductive conductivity sensor – NEW
VAT invoice will be provided. Advertised else where!
Product characteristics
| Number of inputs and outputs |
Number of analogue outputs: 1 |
| Process connection |
G 1 external thread Aseptoflex Vario |
Application
| Special feature |
Gold-plated contacts |
| Media |
conductive liquids |
| Note on media |
|
| Cannot be used for |
See the operating instructions, chapter “Function and features”. |
| Medium temperature [°C] |
-25…100; (< 1 h: 150) |
| Pressure rating [bar] |
16 |
| Vacuum resistance [mbar] |
-1000 |
| Operating voltage [V] |
18…30 DC |
| Current consumption [mA] |
< 50 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
2 |
| Measuring principle |
inductive |
|
| Total number of outputs |
1 |
| Output signal |
analogue signal; IO-Link |
| Output function |
analogue output; scalable; selectable conductivity / temperature |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20 |
| Max. load [Ω] |
500 |
| Measuring range [µS/cm] |
100…1000000 |
| Resolution [µS/cm] |
| 0…10.000 |
1 |
| 10.000…100.000 |
10 |
| 100.000…1.000.000 |
100 |
|
| Accuracy (in the measuring range) |
2 % MW ± 25 µS/cm |
| Drift [%/K] |
0,1 %/K MW ± 25 µS/cm |
| Repeatability |
1 % MW ± 25 µS/cm |
| Long-term stability |
0,5 % MW ± 25 µS/cm |
| Measuring range [°C] |
-25…150 |
Reviews